Recent Installations

Direct Fired Heater - 11017

CONKLIN, ALBERTA, CANADA
  • (1) Unit - 40.944 MM BTU/hr
  • Glycol Heater

Simple Cycle Catalyst Systems for Pratt & Whitney FT8 TwinPacs - 0337

KLAMATH FALLS, OREGON
  • (4) Units - (56 MW per TwinPac) 
  • Catalyst Systems: NOx (SCR) Retrofit (CO pre-existing)

 

Simple Cycle Catalyst System for ABB GT10B2 - 0128

CLATSKANIE, OREGON
  • (1) Unit - (25 MW) Gas Turbine
  • Catalyst Systems: CO Only

Simple Cycle Catalyst Systems for GE LM6000 - 0123

WEST VALLEY, UTAH
  • (4) Units - (45 MW) Gas Turbines
  • Catalyst Systems: NOx and CO

Simple Cycle Catalyst Systems for GE LM6000 - 0152

SALT LAKE CITY, UTAH
  • (3) Units - (45 MW) Gas Turbines
  • Catalyst Systems: NOx and CO

Simple Cycle Catalyst Systems for GE LM6000 -0283

PASADENA, CALIFORNIA
  • (2) Units - (45 MW) Gas Turbines
  • Catalyst Systems: NOx and CO

Simple Cycle Catalyst Systems for GE LM6000 - 0449

RIPON, CALIFORNIA
  • (2) Units - (45 MW) Gas Turbines
  • Catalyst Systems: NOx and CO

Simple Cycle Catalyst Systems for GE LM6000 - 0453

RIVERSIDE, CALIFORNIA
  • (2) Units - (45 MW) Gas Turbines
  • Catalyst Systems: NOx and CO

Simple Cycle Catalyst System for GE LM6000 - 0417

SAN DIEGO, CALIFORNIA
  • (1) Unit - (45 MW) Gas Turbine
  • Catalyst Systems: NOx and CO

Simple Cycle Catalyst Systems for GE LM6000 - 0676

LOS ANGELES, CALIFORNIA
  • (5) Units - (45 MW) Gas Turbines
  • Catalyst Systems: NOx and CO

Simple Cycle Catalyst Systems for GE LM6000 - 0698

NILAND, CALIFORNIA
  • (2) Units - (45 MW) Gas Turbines
  • Catalyst Systems: NOx and CO

Simple Cycle Catalyst System for GE LM6000 - 07018

YUMA, ARIZONA
  • (2) Units - (45 MW) Gas Turbines
  • Catalyst Systems: NOx and CO

Simple Cycle Catalyst System for GE LM6000 - 07025

MIRAMAR, CALIFORNIA
  • (1) Unit - (45 MW) Gas Turbine
  • Catalyst System: NOx and CO

Simple Cycle Catalyst Systems for GE LM6000 - 07046

WINCHESTER, TEXAS
  • (4) Units (45 MW) Gas Turbines
  • Catalyst Systems: NOx and CO

Simple Cycle Catalyst Systems for GE LM6000 - 07058

AUSTIN, TEXAS
  • (2) Units - (45 MW) Gas Turbines
  • Catalyst Systems: NOx Only

Simple Cycle Catalyst Systems for GE LMS100 - 07038

LAREDO, TEXAS
  • (2) Units - (100 MW) Gas Turbines
  • Catalyst  Systems: NOx and CO

Heat Recovery Steam Generators for GE Frame 6B - 1085

ANACORTES, WASHINGTON
  • (2) Units - (40 MW) Gas Turbines
  • HP Steam: 300,000 lb/hr - 650 psig @ 720ºF

Heat Recovery Steam Generators for GE Frame 6B - 1117

ANACORTES, WASHINGTON
  • (3) Units - (40 MW) Gas Turbines
  • HP Steam: 300,000 lb/hr - 650 psig @ 720ºF

Heat Recovery Steam Generator for GE Frame 6B - 1105

NORTH TONAWANDA, NEW YORK
  • (1) Unit - (40 MW) Gas Turbine
  • HP Steam: 135,000 lb/hr - 1265 psig @ 950ºF
  • LP Steam: 27,000 lb/hr - 305 psig @ 487ºF

Heat Recovery Steam Generators for GE Frame 6B - 0261

MONTEGO BAY, JAMAICA
  • (2) Units - (40 MW) Gas Turbines
  • HP Steam: 148,000 lb/hr - 986 psig @ 977ºF
  • LP Steam: 10,700 lb/hr - 98 psig @ 483ºF

Heat Recovery Steam Generator for GE Frame 6FA - 1123

PINION PINES, NEVADA
  • (1) Unit (70 MW) Gas Turbine
  • HP Steam: 175,000 lb/hr - 943 psig @ 950ºF
  • LP Steam: 45,000 lb/hr - 48 psig @ 350ºF
  • Superheat Steam: 155,000 lb/hr - 943 psig @ 950ºF

Heat Recovery Steam Generators for GE Frame 7EA - 1078

POINT COMFORT, TEXAS
  • (5) Units - (85 MW) Gas Turbines
  • HP Steam: 364,000 lb/hr - 1350 psig @ 905ºF
  • LP Steam: 60,000 lb/hr - 300 psig @ 500ºF

Heat Recovery Steam Generator for GE Frame 7EA - 1149

GAINESVILLE, FLORIDA
  • (1) Unit (85 MW) - Gas Turbine
  • HP Steam: 284,000 lb/hr - 925 psig @ 955ºF
  • LP Steam: 52,000 lb/hr - 36 psig @ 304ºF

Heat Recovery Steam Generators for GE Frame 7EA - 0016

SASKATOON, SASKATCHEWAN, CANADA
  • (2) Units - (85 MW) Gas Turbines
  • HP Steam: 582,000 lb/hr - 1381 psig @ 967ºF
  • IP Steam: 10,000 lb/hr - 308 psig @ 452ºF
  • LP Steam: Sufficient for Integral Deaeration

Heat Recovery Steam Generators for GE Frame 7FA - 1143

DENVER CITY, TEXAS
  • (2) Units - (165 MW) Gas Turbines
  • HP Steam: 556,380 lb/hr - 1538 psig @ 990ºF
  • Reheat Steam: 474,598 lb/hr - 358 psig @ 1005ºF
  • IP Steam: 42,691 lb/hr - 376 psig @ 621ºF
  • LP Steam: 2,501 lb/hr - 65 psig @ 467ºF

Heat Recovery Steam Generators for Siemens V84.3A - 1148

GLENNONVILLE, MISSOURI
  • (2) Units - (170 MW) Gas Turbines
  • HP Steam: 373,000 lb/hr - 1645 psig @ 1003ºF
  • Reheat Steam: 450,000 lb/hr - 396 psig @ 1003ºF
  • IP Steam: 83,000 lb/hr - 405 psig @ 610ºF
  • LP Steam: 51,4000 lb/hr - 51 psig @ 459ºF

Heat Recovery Steam Generators for EGT Typhoons - 1136

HANOVER PARK, ILLINOIS
  • (3) Units - (4 MW) Gas Turbine
  • HP Steam: 34,000 lb/hr - 615 psig @ 750ºF
  • LP Steam: Sufficient for Integral Deaeration

Heat Recovery Steam Generator for ABB GT10 - 1116

CAMBRIDGE, MASSACHUSETTS
  • (1) Unit - (25 MW) Gas Turbine
  • LP Steam: 166,000 lb/hr - 232 psig @ 450ºF

Heat Recovery Steam Generators for Rolls Royce RB211 - 0525

VILLAHERMOSA, MEXICO
  • (2) Units - (27.5 MW) Gas Turbines
  • HP Steam: 94,900 lb/hr - 900 psig @ 950ºF
  • LP Steam: Sufficient for Integral Deaeration

Heat Recovery Steam Generator for Siemens SGT800 - 0812

REDDING, CALIFORNIA
  • (1) Unit - (40 MW) Gas Turbine
  • HP Steam: 140,000 lb/hr - 637 psig @ 755ºF
  • LP Steam: Sufficient for Integral Deaeration

Heat Recovery Steam Generator for Siemens SGT700 - 07027

CALLAO, PERU
  • (1) Unit - (29 MW) Gas Turbine
  • HP Steam: 127,900 lb/hr - 667 psig @ 806ºF

Heat Recovery Steam Generator for GE LM2500 - 1072

LUBBOCK, TEXAS
  • (1) Unit - (23 MW) Gas Turbine
  • HP Steam: 65,000 lb/hr - 645 psig @ 750ºF
  • LP Steam: Integral Deaerator

Heat Recovery Steam Generators for GE LM2500 - 1114

TUPMAN, CALIFORNIA
  • (2) Units - (23 MW) Gas Turbine
  • HP Steam: 145,000 lb/hr - 515 psig @ 604ºF

Heat Recovery Steam Generator for GTX100 - 0018

REDDING, CALIFORNIA
  • (1) Unit - (42 MW) Gas Turbine
  • HP Steam: 140,000 lb/hr - 637 psig @ 755ºF
  • LP Steam: Sufficient for Integral Deaeration

Heat Recovery Steam Generators for GE LM6000 - 0010

CARSELAND, ALBERTA, CANADA
  • (2) Units - (43MW) Gas Turbines
  • HP Steam: 249,000 lb/hr - 907 psig @ 797ºF

 

Heat Recovery Steam Generator for GE LM6000 - 0140

MODESTO, CALIFORNIA
  • (1) Unit (42 MW) Gas Turbine
  • HP Steam: 273,500 lb/hr - 1,300 psig @ 955º
  • LP Steam: 9,000 lb/hr - 102 psig @ 600ºF

Heat Recovery Steam Generators for GE LM6000 - 0295

Santa Clara, California
  • (2) Units - (45 MW) Gas Turbine
  • HP Steam:  184,000 lb/hr - 1,275 psig @ 995ºF
  • LP Steam: 33,000 lb/hr - 105 psig @ 581ºF

Simple Cycle Catalyst System for GE LMS100 - 07041

MILLVILLE, NEW JERSEY
  • (1) Unit (100 MW) Gas Turbine
  • Catalyst Systems: CO and NOx

Simple Cycle Catalyst Systems for GE LMS100 - 07047

EDMONTON, ALBERTA, CANADA
  • (2) Units (100 MW) Gas Turbines
  • Catalyst Systems:  NOx only

Simple Cycle Catalyst Systems for GE LMS100 - 07053

TRAPP, KENTUCKY
  • (2) Units (100 MW) Gas Turbines
  • Catalyst Systems:  NOx and CO

Simple Cycle Catalyst System for GE LM6000 - 08026

ST. GEORGE, UTAH
  • (1) Unit - (45 MW) Gas Turbine
  • Catalyst Systems:  NOx and CO

Simple Cycle Catalyst Systems for GE LM6000 - 09002

MILFORD, CONNECTICUT
  • (4) Units (45 MW) Gas Turbines
  • Catalyst Systems:  NOx and CO

Direct Fired Heaters - 0658

LAKE CHARLES, LOUISIANA
  • (2) Units - 150.00 MM BTU/hr
  • Glycol Heaters / Burner Management Skids

Simple Cycle Catalyst Systems for GE LM6000 - 08043

Coolidge, Arizona
  • (12) Units - (45 MW) Gas Turbines
  • Catalyst Systems:  CO and NOx

Once-Through Steam Generators - 10017

ALBERTA, CANADA
  • (18) Units - 242 MM BTU/hr
  • 1372 psig

Once-Through Steam Generators - 0490

ALBERTA, CANADA
  • (5) Units - 248.6 MM BTU/hr
  • 1595 psig

Once-Through Steam Generators - 0478

ALBERTA, CANADA
  • (6) Units - 245 MM BTU/hr
  • 1398 psig

Heat Recovery Steam Generator for GE LM6000 - 08036

Houston, Texas
  • (1) Unit - (43 MW) Gas Turbine
  • HP Steam: 237,000 lb/hr - 435 psig @ 600ºF
  • LP Steam: 97,000 lb/hr - 170 psig Sat
  • Supplement Firing - 220 mm BTU/hr
  • Catalyst System: NOx

Heat Recovery Steam Generator for GE LM2500+G4 - 09039

COLLEGE STATION, TEXAS
  • (1) Unit - (33 MW) Gas Turbine
  • HP Steam: 192,000 lb/hr - 450 psig @ 665ºF
  • Supplemental Firing: 115 mm BTU/hr